or ₦547,238/month
Installed price, equipment and installation included
⚡Over 2,500+ Homes & Businesses Powered Across Nigeria
For filling stations
Pumps, canopy lights and the shop
18kWp solar · 20kVA hybrid inverter · 30.72kWh lithium · ₦21.4M
or ₦998,054/month
Package price: all the equipment below, installed and commissioned.
Delivery to Estimated, Monday to Saturday. Installation is booked after delivery.
Today₦5,342,375
Then 12 × monthly₦1,658,550
Total ₦25,244,977, of which ₦3,875,477 is the cost of credit (42% APR, indicative). A bigger deposit or shorter term lowers the total. Your lender confirms the final terms before you commit.
18 kWp
Solar array (30 panels)
20 kVA
Inverter
30.72 kWh
Battery
60.8 kWh
Solar a day (Lagos)
₦21.4M
Installed price
Pay outright
₦21,369,500
Equipment, installation and commissioning. Delivery is added at checkout.
Pay Small Small
₦5,342,375 down
then 12 payments of ₦1,658,550
Example at the minimum 25% deposit. Choose 3 to 24 months above; credit by our lending partner, subject to approval.
Not recommended for: Running more than about 16kW at once.
Designed for this load, with about 14 hours of backup at night. On a sunny day the panels cover about 72% of it.
4× Fuel dispensers
14 hours a day · about 750W each
12× Canopy floodlights
12 hours a day · about 100W each
2× 1.5HP AC
10 hours a day · about 1.3kW each
1× Chest freezer
24 hours a day · about 200W each
27.6 kWh
Usable of 30.72 kWh, without shortening battery life
4.2 hours
At your evening load (about 6kW)
3.6 hours
With everything above on at once (about 7kW)
Overnight: with the appliances above on their usual evening hours, a full battery carries you for about 4.2 hours. Plan about 14 hours by switching off the heaviest loads late at night. The panels recharge it the next day.
The Filling Station 20kW, hour by hour, with NEPA off all day. Watch the sun charge the battery, the battery carry the night, and see when, if ever, the generator has to start. Pick a kind of day to see how it copes when the sun is weak.
12:00 pm
Best day · NEPA off
On a best day (about 167 a year), the panels fill the battery and its lowest point is 66%. The generator never starts.
22 kWh
Solar used
21 kWh
House used
66%
Battery lowest
None
Generator
| Hour | Panels make | Solar to house | Solar to battery | Battery to house | Generator | House | Battery at end |
|---|---|---|---|---|---|---|---|
| 12am | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 73% |
| 1am | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 71% |
| 2am | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 70% |
| 3am | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 69% |
| 4am | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 68% |
| 5am | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 66% |
| 6am | 0 kW | 0 kW | 0 kW | 0.2 kW | 0 kW | 0.2 kW | 66% |
| 7am | 0.6 kW | 0 kW | 0.6 kW | 0 kW | 0 kW | 0 kW | 68% |
| 8am | 2.9 kW | 0 kW | 2.9 kW | 0 kW | 0 kW | 0 kW | 77% |
| 9am | 7.1 kW | 1.4 kW | 5.6 kW | 0 kW | 0 kW | 1.4 kW | 97% |
| 10am | 12 kW | 1.4 kW | 0.9 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| 11am | 16 kW | 1.4 kW | 0 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| noon | 18 kW | 1.4 kW | 0 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| 1pm | 17 kW | 1.4 kW | 0 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| 2pm | 13 kW | 1.4 kW | 0 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| 3pm | 8.3 kW | 1.4 kW | 0 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| 4pm | 3.8 kW | 1.4 kW | 0 kW | 0 kW | 0 kW | 1.4 kW | 100% |
| 5pm | 1 kW | 0.9 kW | 0 kW | 0.5 kW | 0 kW | 1.4 kW | 98% |
| 6pm | 0.1 kW | 0.1 kW | 0 kW | 1.5 kW | 0 kW | 1.6 kW | 92% |
| 7pm | 0 kW | 0 kW | 0 kW | 1.1 kW | 0 kW | 1.1 kW | 88% |
| 8pm | 0 kW | 0 kW | 0 kW | 1.1 kW | 0 kW | 1.1 kW | 84% |
| 9pm | 0 kW | 0 kW | 0 kW | 1.1 kW | 0 kW | 1.1 kW | 79% |
| 10pm | 0 kW | 0 kW | 0 kW | 1.1 kW | 0 kW | 1.1 kW | 75% |
| 11pm | 0 kW | 0 kW | 0 kW | 0.3 kW | 0 kW | 0.3 kW | 74% |
Kinds of day and how often they happen come from NASA POWER satellite data for Lagos, 2021 to 2023 (daily sunlight: best 5 kWh/m² or more, good 4–5, fair 3–4, poor 2–3, worst under 2). Panels are rated in kWp: in clear midday sun they make their rated kW, less on cloudy days. Inverters carry their full rating (1kVA = 1kW). The simulation assumes NEPA is off all day, the panels out-produce the house from 8am to 5pm with the rest filling the battery, and a home that uses most of its power after 6pm, about 21 kWh a day: the appliance list above trimmed to what this system can carry with no grid at all (the full list, about 85 kWh a day, assumes some grid power). The generator starts only when the battery is empty. Estimates; your engineer confirms them at the site survey.
| Solar array | 18 kWp |
|---|---|
| Panels | 30 × Canadian Solar BiHiKu7 600W Bifacial |
| Inverter | 1 × Deye SUN-20K-SG01HP3 20kW 3-Phase Hybrid |
| Phase | Three-phase |
| Battery | 2 × Pylontech Force L2 15.36kWh Stack |
| Battery capacity | 30.72 kWh (27.6 kWh usable) |
| Battery chemistry | LiFePO₄ (lithium iron phosphate) |
| Battery cycle life | 6,000+ cycles |
| Battery warranty | 10 years |
| Solar energy a day | About 60.8 kWh in Lagos |
| Solar energy a month | About 1,847 kWh |
| Roof space needed | About 98 m² |
| Runs at once | About 16kW comfortably |
Estimated against running a 20kVA diesel generator. The more of your power you use in daylight, the faster it pays back.
Conservative
You use 60% of what the panels make
₦649,545 saved a month
2.7 years to pay back ₦21.4M
Typical
You use 75% of what the panels make
₦811,932 saved a month
2.2 years to pay back ₦21.4M
Daytime-heavy use
You use 90% of what the panels make
₦974,318 saved a month
1.8 years to pay back ₦21.4M
A 20kVA diesel generator running 10 hours a day at half load burns about 1,008 litres a month. At ₦1,400 a litre that is ₦1,410,609 in fuel, before servicing, oil and repairs: about ₦586 for every kWh it makes. These panels make about 60.8 kWh on a sunny day, and the battery carries the evening.
Work it out with your own fuel spendSolar output: 18 kWp × 4.5 peak sun hours a day (Lagos) × 0.75 for heat, dust and wiring losses. Savings: the share of that output you use, valued at what the same energy costs from the generator. Generator fuel: litres per hour = 0.246 × kW drawn + 0.084 × rated kW (the standard fuel curve used in energy-planning tools), at half load, with diesel at ₦1,400 a litre and ₦15,000 a month for servicing. Small petrol sets usually burn more than this curve suggests, so real savings are often higher. Battery hours use 90% of lithium and 50% of lead-acid capacity and 92% inverter efficiency. Estimates, not a guarantee: an engineer confirms your numbers at the site survey.
Examples with the minimum 25% deposit. Choose your own deposit and term (3 to 24 months) above; your exact quote comes from our lending partners at checkout.
| Tenor | Down payment | Monthly | Total |
|---|---|---|---|
| 3 months | ₦5,342,375 | ₦5,720,629 | ₦22,504,261 |
| 6 months | ₦5,342,375 | ₦3,007,782 | ₦23,389,066 |
| 12 months | ₦5,342,375 | ₦1,658,550 | ₦25,244,977 |
| 18 months | ₦5,342,375 | ₦1,215,126 | ₦27,214,643 |
| 24 months | ₦5,342,375 | ₦998,054 | ₦29,295,682 |
APR shown on your quote before you apply. Credit disclosures
Book a free site survey. An engineer checks your roof, your appliances and your wiring, and confirms exactly what the Filling Station 20kW will run and save.
One working day for most homes, after a site survey. You choose your survey date at checkout.
Yes. The 20kVA inverter accepts additional batteries at the same voltage, and we can quote a top-up from your account.
Use Customise this package to swap parts, or run the solar calculator with your own appliances. An engineer checks every order before dispatch.
Yes. The price includes all the equipment listed, installation, commissioning and a 12-month workmanship warranty. Delivery is shown at checkout.
or ₦547,238/month
Installed price, equipment and installation included
or ₦475,500/month
Installed price, equipment and installation included
or ₦242,187/month
Installed price, equipment and installation included